Single Conductor 600V Secondary Type URD Cable Aluminum Conductor
Single Conductor Type URD Cable - Aluminum Conductor
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation.
Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
90ºC conductor temperature, 20ºC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation.
Standards
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
- B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
- B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
- B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
- B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
- Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
- "USE-2" per UL 854 available upon request.
- Cable in Duct (CIC)
- Abrasion Resistant
90ºC conductor temperature, 20ºC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Unit of Measure
Items |
/Asset/SINGLE-URD.jpg Princeton Single Conductor 600V Secondary Type URD Cable Aluminum Conductor |
/Asset/SINGLE-URD.jpg Mercer Single Conductor 600V Secondary Type URD Cable Aluminum Conductor |
/Asset/SINGLE-URD.jpg Clemson Single Conductor 600V Secondary Type URD Cable Aluminum Conductor |
/Asset/SINGLE-URD.jpg Kenyon Single Conductor 600V Secondary Type URD Cable Aluminum Conductor |
/Asset/SINGLE-URD.jpg Harvard Single Conductor 600V Secondary Type URD Cable Aluminum Conductor |
|||||
Size (AWG or kcmil) |
N/A 6 | N/A 4 | N/A 2 | N/A 1 | N/A 1/0 | |||||
Stranding | N/A 7/W | N/A 7/W | N/A 7/W | N/A 19/W | N/A 19/W | |||||
Insulation Thickness (mils) |
N/A 60 mls | N/A 60 mls | N/A 60 mls | N/A 80 mls | N/A 80 mls | |||||
Outside Diameter |
N/A .298 Inches | N/A .345 Inches | N/A .403 Inches | N/A .522 Inches | N/A .482 Inches | |||||
Weight (lb/1000 ft) |
N/A 45 Lbs | N/A 64 Lbs | N/A 93 Lbs | N/A 148 Lbs | N/A 122 Lbs | |||||
Ampacity Direct Burial |
N/A 90 Amps | N/A 120 Amps | N/A 155 Amps | N/A 200 Amps | N/A 175 Amps | |||||
Ampacity In Duct |
N/A 65 Amps | N/A 85 Amps | N/A 115 Amps | N/A 150 Amps | N/A 130 Amps | |||||
|