Print Back

SunGuard® UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V

Applications
UL Type PV conductors are primarily used in free air, conduit or direct burial for wiring of grounded and ungrounded photovoltaic applications in accordance with the NEC. The cable is suitable for use in dry or wetmore

DS2019 PV Duplex.png
Items DS2019 PV Duplex.png
A8-02PV2X0700
SunGuard Paralleled UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Duplex.png
A6-02PV2X0700
SunGuard Paralleled UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Duplex.png
A4-02PV2X0700
SunGuard Paralleled UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Duplex.png
A2-02PV2X0700
SunGuard Paralleled UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Duplex.png
A1-02PV2X1900
SunGuard Paralleled UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
Conductor Size
(AWG or kcmil)
N/A 8 N/A 6 N/A 4 N/A 2 N/A 1
Conductor Diameter
(in)
N/A 0.134 N/A 0.169 N/A 0.213 N/A 0.268 N/A 0.299
Insulation Thickness
(in)
N/A 0.085 N/A 0.085 N/A 0.085 N/A 0.085 N/A 0.105
Diameter
(in)
N/A 0.608 x 0.304 N/A 0.678 x 0.339 N/A 0.766 x 0.383 N/A 0.876 x 0.438 N/A 1.018 x 0.509
AL Weight
(lb / 1000 ft)
N/A 31.0 N/A 49.2 N/A 78.4 N/A 125 N/A 157
Net Weight
(lb / 1000 ft)
N/A 105 N/A 135 N/A 179 N/A 244 N/A 326
DC Resistance
@ 20 deg C
(O / 1000 ft)
N/A 1.072 N/A 0.6742 N/A 0.4239 N/A 0.2666 N/A 0.2114
AC Resistance
@ 90 deg C, 60 Hz
(O / 1000 ft)
N/A 1.347 N/A 0.8473 N/A 0.5304 N/A 0.3353 N/A 0.2661
Inductive Resistance
@ 60 Hz
(O / 1000 ft)
N/A 0.04968 N/A 0.04785 N/A 0.04602 N/A 0.0445 N/A 0.04481
Capacitance
(µF / 1000 ft)
N/A 0.01039 N/A 0.01091 N/A 0.01143 N/A 0.01192 N/A 0.01173