Loose Tube Fiber Optic Double Jacket Double Armored
Loose Tube Fiber Optic Cable
Applications
Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried
Constructions
Dielectric, Armored, Double Armored
Fiber Count
2 to 432 fibers in Color-coded Buffer Tubes
Fiber Types
Single-mode / Multi-mode
Options
Gel-Filled Core / Steel Central Member / Copper Pair(s)
Other versions
Central / Heavy Duty / Indoor-Outdoor
Performance
ANSI/ICEA, IEC, RUS, Telcordia GR-20
Mechanical Specifications
Installation
[+] Maximum installation load 600 lbf (2670 N)
[+] Maximum operation load 180 lbf (800 N)
Temperature Range
[+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
[+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
[+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)
*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)
Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried
Constructions
Dielectric, Armored, Double Armored
Fiber Count
2 to 432 fibers in Color-coded Buffer Tubes
Fiber Types
Single-mode / Multi-mode
Options
Gel-Filled Core / Steel Central Member / Copper Pair(s)
Other versions
Central / Heavy Duty / Indoor-Outdoor
Performance
ANSI/ICEA, IEC, RUS, Telcordia GR-20
Mechanical Specifications
Installation
[+] Maximum installation load 600 lbf (2670 N)
[+] Maximum operation load 180 lbf (800 N)
Temperature Range
[+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
[+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
[+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)
*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)
Items |
![]() LT-DJDA-1 Loose Tube Fiber Optic Double Jacket Double Armored |
![]() LT-DJDA-2 Loose Tube Fiber Optic Double Jacket Double Armored |
![]() LT-DJDA-3 Loose Tube Fiber Optic Double Jacket Double Armored |
![]() LT-DJDA-4 Loose Tube Fiber Optic Double Jacket Double Armored |
![]() LT-DJDA-5 Loose Tube Fiber Optic Double Jacket Double Armored |
|||||
Fiber Count |
N/A 2 to 60 | N/A 62 to 72 | N/A 74 to 84 | N/A 86 to 96 | N/A 98 to 108 | |||||
Number of Buffer Tubes |
N/A 5 | N/A 6 | N/A 7 | N/A 8 | N/A 9 | |||||
Diameter (in) |
N/A 0.67 | N/A 0.7 | N/A 0.74 | N/A 0.78 | N/A 0.810 | |||||
Diameter (mm) |
N/A 17.1 | N/A 17.8 | N/A 18.8 | N/A 19.9 | N/A 20.6 | |||||
Approximate Cable Weight lb/MFT |
N/A 205 | N/A 232 | N/A 253 | N/A 274 | N/A 288 | |||||
Approximate Cable Weight kg/km |
N/A 306 | N/A 346 | N/A 377 | N/A 408 | N/A 428 | |||||
Bend Radius Load (in) |
N/A 13 | N/A 14 | N/A 15 | N/A 16 | N/A 16 | |||||
Bend Radius Load (cm) |
N/A 34 | N/A 36 | N/A 38 | N/A 40 | N/A 41 | |||||
Bend Radius No Load (in) |
N/A 10 | N/A 11 | N/A 11 | N/A 12 | N/A 12 | |||||
Bend Radius No Load (cm) |
N/A 26 | N/A 27 | N/A 28 | N/A 30 | N/A 31 | |||||
|