Print Back

SunGuard® UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc

Applications
UL Type PV conductors are primarily used in free air, conduit or direct burial for wiring of grounded and ungrounded photovoltaic applications in accordance with the NEC. The cable is suitable for use in dry or wet locations at temperatures not to exceed 90°C. The cable is rated 2000 V dc.

Construction
Conductor: Annealed compact stranded AA-8000 series Aluminum Conductor Material (ACM).
Insulation: Abrasion, moisture, and heat resistant colored crosslinked polyethylene (XLPE).
Cable Identification:  Black or Red XLPE  -  Other colors or optional red stripe available upon request
Voltage Rating: 2000 V DC
Temperature Rating: 90°C Dry or Wet
Minimum Bending Radius:

  • Overall Diameter Less than or Equal to 1.000 in
  • Not Under Tension: 4x outer diameter
  • Under Tension (During Pull): 6x outer diameter
  • Overall Diameter Greater than 1.000 in
  • Not Under Tension: 5x outer diameter
  • Under Tension (During Pull): 7.5x outer diameter

Ratings and Markings

  • Sunlight resistant and marked "SUN RES"
  • Direct burial and marked "DIR BUR"
  • Passes cold bend test and cold impact at -40°C and marked "-40C"
  • RoHS Compliant

Standards
These cables are manufactured and tested to meet or exceed the following standards:

  • ASTM B800 -- 8000 Series Aluminum Alloy Wire for Electrical Purposes—Annealed and Intermediate Tempers
  • ASTM B801 -- Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
  • UL 4703 -- Photovoltaic Wire
  • ICEA S-95-658 / NEMA WC70 -- Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

 Listings and Certifications (AWG)   

  • UL listed as Type PV -- File E361222

  

Updated 28 January 2025

 

 

DS2019 PV Wire.png
Unit of Measure
Items DS2019 PV Wire.png
A8-01PV2X0700
SunGuard UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Wire.png
A6-01PV2X0700
SunGuard UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Wire.png
A4-01PV2X0700
SunGuard UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Wire.png
A2-01PV2X0700
SunGuard UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
DS2019 PV Wire.png
A1-01PV2X1900
SunGuard UL Type PV, Aluminum Conductor, 90°C Dry or Wet, Rated 2000 V dc
Conductor Size
(AWG or kcmil)
N/A 8 N/A 6 N/A 4 N/A 2 N/A 1
Conductor Diameter
(in)
N/A 0.134 N/A 0.169 N/A 0.213 N/A 0.268 N/A 0.299
Insulation Thickness
(in)
N/A 0.085 N/A 0.085 N/A 0.085 N/A 0.085 N/A 0.105
Diameter
(in)
N/A 0.304 N/A 0.339 N/A 0.383 N/A 0.438 N/A 0.509
AL Weight
(lb / 1000 ft)
N/A 15.5 N/A 24.6 N/A 39.2 N/A 62.3 N/A 78.6
Net Weight
(lb / 1000 ft)
N/A 52.3 N/A 67.3 N/A 89.3 N/A 122 N/A 163
DC Resistance
@ 20 deg C
(Ω / 1000 ft)
N/A 1.072 N/A 0.6742 N/A 0.4239 N/A 0.2666 N/A 0.2114
AC Resistance
@ 90 deg C, 60 Hz
(Ω / 1000 ft)
N/A 1.347 N/A 0.8473 N/A 0.5304 N/A 0.3353 N/A 0.2661
Inductive Resistance
@ 60 Hz
(Ω / 1000 ft)
N/A 0.04968 N/A 0.04785 N/A 0.04602 N/A 0.0445 N/A 0.04481
Capacitance
(µF / 1000 ft)
N/A 0.01039 N/A 0.01091 N/A 0.01143 N/A 0.01192 N/A 0.01173