12 AWG FR-XLPE Insulated Conductors CU Shield, CPE Jacket, 600V
Control Cable FR-XLPE Insulated Conductors, Copper Tape Shield, CPE Jacket, 600V
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90 ºC maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.
Standards
Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90 ºC maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.
Standards
- TC Type Tray Cable per Article 340 of the NEC.
- Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
- Individual conductors approved as Type XHHW.
- Cables Pass IEEE-383 ribbon burner flame test.
- Overall jacket approved as Sunlight Resistant.
- Cables meet requirements of ICEA Pub. No. S-73-532/NEMA WC74
- Cables may be supplied with an insulated ground and marked ""Open Wiring.""
- Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
- Bare or Tinned Copper
- Flexible stranded conductors
- Color coding: ICEA Method 1, Table E1
- EPR Insulation
- PVC, CSPE, LSOH jackets
- Insulated ground wires or bare ground wires
- Overall copper tape shield
- Overall copper braid shield
- Overall longitudinal corrugated copper shield
- Overall mylar tape shield with drain wire
- 1000 volt rated construction
Item # |
Number
|
Conductor
|
Number
|
Overall Mils |
Overall
|
Weight
|
---|---|---|---|---|---|---|
12-452SH 12-452SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 2 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 45 |
Overall Diameter Inches (mm) N/A 0.49 |
Weight Per (lb/1000 ft) XLP N/A 155 Lbs |
12-453SH 12-453SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 3 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 45 |
Overall Diameter Inches (mm) N/A 0.54 |
Weight Per (lb/1000 ft) XLP N/A 185 Lbs |
12-454SH 12-454SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 4 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 60 |
Overall Diameter Inches (mm) N/A 0.62 |
Weight Per (lb/1000 ft) XLP N/A 245 Lbs |
12-455SH 12-455SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 5 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 60 |
Overall Diameter Inches (mm) N/A 0.67 |
Weight Per (lb/1000 ft) XLP N/A 295 Lbs |
12-456SH 12-456SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 6 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 60 |
Overall Diameter Inches (mm) N/A 0.70 |
Weight Per (lb/1000 ft) XLP N/A 340 Lbs |
12-457SH 12-457SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 7 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 60 |
Overall Diameter Inches (mm) N/A 0.73 |
Weight Per (lb/1000 ft) XLP N/A 340 Lbs |
12-458SH 12-458SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 8 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 60 |
Overall Diameter Inches (mm) N/A 0.86 |
Weight Per (lb/1000 ft) XLP N/A 395 Lbs |
12-462SH 12-462SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 12 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 0.95 |
Weight Per (lb/1000 ft) XLP N/A 610 Lbs |
12-464SH 12-464SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 14 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.04 |
Weight Per (lb/1000 ft) XLP N/A 690 Lbs |
12-465SH 12-465SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 15 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.20 |
Weight Per (lb/1000 ft) XLP N/A 770 Lbs |
12-466SH 12-466SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 16 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.22 |
Weight Per (lb/1000 ft) XLP N/A 780 Lbs |
12-468SH 12-468SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 18 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.25 |
Weight Per (lb/1000 ft) XLP N/A 865 Lbs |
12-469SH 12-469SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 19 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.25 |
Weight Per (lb/1000 ft) XLP N/A 865 Lbs |
12-470SH 12-470SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 20 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.31 |
Weight Per (lb/1000 ft) XLP N/A 940 Lbs |
12-475SH 12-475SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 25 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.39 |
Weight Per (lb/1000 ft) XLP N/A 1175 Lbs |
12-477SH 12-477SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 27 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.41 |
Weight Per (lb/1000 ft) XLP N/A 1200 Lbs |
12-479SH 12-479SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 29 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.42 |
Weight Per (lb/1000 ft) XLP N/A 1270 Lbs |
12-481SH 12-481SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 31 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.44 |
Weight Per (lb/1000 ft) XLP N/A 1425 Lbs |
12-482SH 12-482SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 32 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.47 |
Weight Per (lb/1000 ft) XLP N/A 1425 Lbs |
12-487SH 12-487SH/Asset/xlpe-copper-shield.jpg |
Number of Conductors N/A 37 |
Conductor Size AWG N/A 12 |
Number of Strands N/A 7 |
Overall Mils N/A 80 |
Overall Diameter Inches (mm) N/A 1.53 |
Weight Per (lb/1000 ft) XLP N/A 1545 Lbs |